Dimmable T12 LED Tube

Dimmable T12 LED Tube

Designed for layer and breeder houses, this dimmable T12 LED tube combines broad coverage with gradual light control. Its smooth body also makes routine cleaning easier.

  • Wide-Area Coverage: Double V-shape distribution helps reduce shadowed rows.
  • Gradual Light Control: Flicker-free TRIAC dimming to 0.2% supports smooth transitions; 0-10V is available.
  • Retrofit Flexibility: The T12 form offers a practical alternative to CFL and CCFL lamps.
  • Easier Cleaning: The smooth tube body limits dirt build-up between routine washdowns.

Description

Layer & Breeder Poultry LED Tube Lighting (T12 Series)

Developed for layer and breeder projects, this dimmable T12 LED tube supports poultry-house retrofit planning. Available white, red/blue and switchable two-color options help match the tube to the flock type and lighting schedule without changing the overall layout.

Uniform 300° Double V-Shape Lighting for Layer & Breeder Houses

The double V-shape design combines two 150° beam angles for broad distribution in vertically suspended installations. Its 300° coverage helps planners light layer and breeder house rows more evenly and reduce shadows between fixtures.

TRIAC & 0-10V Dimmable Control for Poultry Light Programs

Flicker-free TRIAC dimming down to 0.2% supports gradual dawn and dusk changes. A 0-10V option can connect to compatible controls, allowing farms to follow a planned light schedule rather than rely on abrupt on/off steps. Match the controller to channel count and connected load.

Retrofit T12 LED Tube Solution for CFL & CCFL Replacement

As an alternative to CFL and cold cathode (CCFL) lamps, this T12 tube supports poultry-house retrofit projects. Lengths of 600, 1200, 1500 and 1800 mm, a 300 mm cable and a 38 mm diameter give installers choices for different house sections and mounting routes.

Easy-Clean Tube Design for Poultry House Lighting

The smooth tube body and lamp cap help limit dirt build-up, making routine cleaning easier in busy poultry houses. Match the selected sealing and material specification to the planned washdown routine to reduce avoidable maintenance.

Contact szAMB team to discuss the appropriate tube length, spectrum and dimming control for your poultry-lighting project.

Dimmable T12 LED Tube Technical Specifications

Review the T12 LED tube specifications first, then select the poultry lighting control system according to the required dimming method, channel count and connected load.

T12 LED Tube Product Specification

Parameter

Available Specification

Selection Relevance

Product series

T12 LED Tube; catalog model ACL-T12-L (verify model mapping)

Confirm the final sales model for layer and breeder poultry projects.

Optical design

Double V-shape; 2 x 150° beam angle (verify by model)

Broad distribution for vertically suspended layouts.

Dimming

TRIAC down to 0.2%; 0-10V option (verify by version)

Match the dimming method to the selected controller.

Spectrum options

White; red/blue; switchable two-color option

Choose according to bird type and lighting program.

Dimensions

600 / 1200 / 1500 / 1800 mm; Ø38 mm; 300 mm cable

Match the fixture length and cable reach to the house layout.

Environmental design

IP67; ammonia and acid resistance (confirm for selected model)

Check model-specific reports and material documentation before publishing claims.

Efficacy and life

Up to 130 lm/W; over 80,000 hours; 5-year warranty (verify)

Supports energy and replacement-cycle evaluation.

 

Master and Slave Controller Options

The existing page lists TRIAC and Bimos master-and-slave controller options. Present them as system-control data, separate from the T12 fixture specification.

 

Control Mode

Model No.

Output

110V Load

220V Load

Input

TRIAC Master & Slave

AMB-IDS-2000-1C

1 AC output x 10A; 1 channel; 1 x 0-10V input

1100W

2200W

AC100-240V, 50/60 Hz

TRIAC Master & Slave

AMB-IDS-4000-2C

2 AC outputs x 10A; 2 channels; 2 x 0-10V inputs

2200W

4400W

AC100-240V, 50/60 Hz

Bimos Master & Slave

AMB-IDS-2000-1C

1 AC output x 10A; 1 channel; 1 x 0-10V input

1100W

2200W

AC100-240V, 50/60 Hz

Bimos Master & Slave

AMB-IDS-4000-2C

2 AC outputs x 10A; 2 channels; 2 x 0-10V inputs

2200W

4400W

AC100-240V, 50/60 Hz

 

 

0-10V Controller Options

Model No.

Channels

0-10V Outputs

Maximum per Output

Input

AMB-IDS-1L

1

3

25 pcs

AC100-240V, 50/60 Hz

AMB-IDS-2L

2

6

25 pcs

AC100-240V, 50/60 Hz

AMB-IDS-6L

6

6

25 pcs

AC100-240V, 50/60 Hz

Dimmable T12 LED Tube FAQ for Layer & Breeder Poultry

Why choose a double V-shape T12 LED tube for layer and breeder poultry?

This T12 LED tube combines two 150° beam angles to create broad distribution in vertically suspended layer and breeder house layouts. Mounting height, row spacing and target light level should determine the final fixture layout.

Which dimmable T12 LED tube length should I choose for my poultry house?

Choose from 600, 1200, 1500 and 1800 mm lengths according to the house section, mounting arrangement and required fixture spacing. The 300 mm cable and 38 mm tube diameter should also be checked against the installation route and mounting accessories.

Should I use TRIAC or 0-10V control for dimmable poultry lighting?

Select the dimming method that matches the planned control system. TRIAC dimming supports flicker-free output down to 0.2%, while 0-10V is available for compatible control systems. Confirm the channel count and connected load before choosing a controller.

Which spectrum option is suitable for layer and breeder poultry lighting?

White, red/blue and switchable two-color options are available. The appropriate selection depends on the bird type and lighting schedule used by the farm. Provide the current lighting program when requesting a dimmable T12 LED tube recommendation.

What should I check before using this T12 tube in a humid poultry house?

The smooth tube body is intended to simplify routine cleaning in poultry houses. Confirm the IP rating and material resistance for the selected model, and request its applicable test documents when the project specifies a particular washdown or corrosion-resistance requirement.

Contact Us